We are china Professional D&R Quantum Magnetic Analyzer,Hunter 4025,3D-NLS non Liner system,9d nls,8d lirs, High potential therapy device,detox foot SPA,iridology camera,factory.Offer OEM.

Vg70 Mobile Icu Ventilator Including Bivent And Prvc Invasive And Noninvasive Ventilator Turbine Ventilator

MAIKONG-Vg70 Mobile Icu Ventilator Including Bivent And Prvc Invasive And Noninvasive Ventilator Turbine Ventilator

Mobile ICU ventilator including BIVENT and PRVC Invasive and Noninvasive Ventilator Turbine Ventilator

VG70

Product Description VG70 VentilatorSuperior Mobile ICU ventilator• Comprehensive ICU ventilator including BIVENT and PRVC• Compact, big capacity battery, no air compressor, intra-hospital mobility• Flexible device configuration: equipped on a trolley, bed or ceiling pendantCost Effective Solution• Unique metal-based, autoclavable, heated exhalation valve• Built-in flow sensor, non-consumable design• Upgradeable ventilation system software, with an available USB portAn Optimal Combination of Invasive and Noninvasive VentilatorAs noninvasive ventilation is used increasingly in a wide range of clinical situations, we offer a dual solution. VG70 combines the advantages of a flexible noninvasive ventilator with a full-featured invasive ventilator for the ICU.

Ventilation Settings

Ventilation Modes

• VCV (A/C), PCV (A/C), PRVC (optional), PSV (optional), STANDBY • SIMV (VCV)+PSV, SIMV (PCV)+PSV, SIMV (PRVC)+PSV • SPONT/CPAP+PSV • BIVENT/APRV +PSV (optional) • NIV/CPAP, NIV-T, NIV-S/T

Enhancements

• Apnea ventilation, Pressure and Flow trigger, Automatic Tube Compensation (ATC), Smart suction • Manual breath, Insp/Exphold, Screen freeze, Nebulization, Lung recruitment

Parameters

Tidal volume (VT)

20-2000ml

Respiratory rate (RR)

1 to 80 bpm

Inspiratory time (Ti)

0.2 to 9 s (adult), 0.2 to 5 s (pediatric)

Inspiratory flow (Flow)

0 to 100 L/min (pediatric), 0 to 180L/min (adult)

Inspiratory pressure (Pinsp)

5 to 70 mbar (or cmH2O)

Inspiratory pressure limit (Pmax)

80 mbar (or cmH2O)

PEEP

0 to 35 mbar (or cmH2O)

Tslope

0 to 2 s

O2 concentration (FiO2)

21 to 100 Vol%

Trigger sensitivity

0.5 to 20 L/min (Flow trigger), -20 to 0 mbar (or cmH2O) (Pressure trigger)

I/E ratio

1/10 to 4/1

Apnea alarm time

10-60 seconds

Monitoring

• Inspiratory O2 concentration (FiO2), End-expiratory CO2 concentration (etCO2) • Compliance (dynamic & static), Resistance (R), MVleak, RSBI, WOB, I:E, Vdaw, PEEPi • Pressure-Volume loop, Pressure-Flow loop, Flow-Volume loop

Alarms

Expiratory minute volume (MV) High/Low, Airway pressure (Paw) High/Low, VTe Low, PEEP High/Low, Insp. O2 concentration (FiO2) High/Low, End-expiratory CO2 concentration (etCO2) High/Low, fspont High, Apnea alarm, Disconnection, Flow sensor error, Gas supply, Electrical supply & battery failure, Exhalation obstruction, Apnea backup for low frequency alarm

Dimensions (WxDxH)

375mm x 395mm x 430mm

Weight

17kg (37.5lbs)

Screen

12.1" TFT color touch screen

MAIKONG400A Hospital ICU mediical wih air compressor ventilator breathing apparatus

Specifications

Display

10.4 TFT Color Screen

mode

A/C,A/C+SIGH,SIMV,SIMV+PSV,PCV,PSV,MMV,PEEP,CPAP

MV

1.0~30.0L/min

PSV pressure

0~3.5kpa

adjustable oxygen concentration

21~100%

trigger sensitivity

-0.1~2.0kpa off

inspiration plateau

0~50%

I:E ratio

3:1~1:3

Tidal Volume

50~500ML

breath frequency

2~60BPM

Apnea alarm and setting

3~12S

monitor wave

P-T,F-T

flow

50L/MIN

precision of air filtration

0.04um

Contact Person:Iris Chen

/Wechat/Mob:+8613826442089

Skype: ysenmediris

Have any question, Please enter the form below and click the submit button.


*
*
*
* + * = ?
Please enter the answer to the sum & Click Submit to verify your registration.

If the submission is unsuccessful, please refresh your browser page and resubmit.


Related Items