Maikong-h602 Popular Medical Portable Icu Ventilator System Hospital Respirator Machine For Hot Sale

MAIKONG-Maikong-h602 Popular Medical Portable Icu Ventilator System Hospital Respirator Machine For Hot Sale

Popular Medical Portable ICU Ventilator

System Hospital Respirator Machine For Hot

Sale

MAIKONG-H602

Medical Portable ICU Ventilator System

me

The machine is suitable for adults and children, microcomputer control, LCD display, pneumatic electronic control ventilator, light touch key to set working parameters, pressure light column to monitor airway pressure at any time, the machine can be used with or without electricity, with lithium battery, if the battery is exhausted, it can control breathing manually.It is necessary equipment for family, field, emergency vehicle and emergency room.

1. Breathing mode:

Synchronous (A / C), forced (IPPV), manual

2. Air circuit performance:

Inspiratory oxygen concentration: 45%, 100%

3. Ventilation performance:

a) Respiratory rate: 6-60 times / min, continuously adjustable.

b) Synchronous inspiratory time: 0.2-2s, continuously adjustable.

c) Tidal volume: 100-1000ml, continuously adjustable.

d) The ratio of suction and respiration: 1:1, 1:2, 1:3, 1:4, 1:5, 2:1, 2:3, 3:5, continuously adjustable.

4. Alarm performance:

a) Pressure upper limit alarm: 2-6kpa, continuously adjustable.

b) Pressure lower limit alarm: 0 ~ 2KPa, continuously adjustable.

c) Battery under voltage alarm: audible and visual alarm.

d) Mute: no less than 2min.

5. Monitoring performance:

a) Tidal volume.b) Respiratory rate.c) Respiratory ratio D) synchronization time

6. Overall performance:

a) Power supply: AC 220V ± 22V 50Hz ± 1Hz

Built in lithium 7.2V power supply battery

b) Host power: 25VA.

c) Electrical safety: meet the relevant requirements of GB9706.1-2007 medical electrical equipment Part I: General requirements for safety for type II B application part of equipment.

7. Service conditions:

a) Ambient temperature: + 5 ℃ ~ + 40 ℃.

b) Relative humidity: 30% – 75%.

c) Atmospheric pressure: 96-104kpa.

d) Use air source: oxygen 0.25-0.3mpa.

8. Storage and transportation:

The normal storage and transportation temperature range of the product is – 18 ℃ ~ + 50 ℃, the relative humidity range is 15% ~ 95%, and the atmospheric pressure range is 70kpa ~ 110kpa. There is no corrosive gas and well ventilated place. During the transportation, it should be moisture-proof, handle with care, and pay attention to the direction sign.

dica

l vento

medical ventilator